• ibhena_lekhanda_01

I-router yeselula ye-MOXA OnCell G4302-LTE4 Series

Incazelo emfushane:

Uchungechunge lwe-MOXA OnCell G4302-LTE4 iyi-LTE Cat yezimboni enamachweba amabili. Ama-router eselula avikelekile angu-4.


Imininingwane Yomkhiqizo

Amathegi Omkhiqizo

Isingeniso

Uchungechunge lwe-OnCell G4302-LTE4 luyi-router yeselula evikelekile nethembekile enombozo we-LTE womhlaba wonke. Le router inikeza ukudluliselwa kwedatha okuthembekile kusuka ku-serial kanye ne-Ethernet kuya ku-interface yeselula engahlanganiswa kalula nezinhlelo zokusebenza ezindala nezesimanje. Ukuphindaphinda kwe-WAN phakathi kwe-interface yeselula kanye ne-Ethernet kuqinisekisa isikhathi esincane sokungasebenzi, kuyilapho futhi kunikeza ukuguquguquka okwengeziwe. Ukuze kuthuthukiswe ukuthembeka nokutholakala kokuxhumeka kweselula, uchungechunge lwe-OnCell G4302-LTE4 lune-GuaranLink enamakhadi e-SIM amabili. Ngaphezu kwalokho, uchungechunge lwe-OnCell G4302-LTE4 lune-input yamandla amabili, i-EMS ephezulu, kanye nokushisa okubanzi kokusebenza kokusetshenziswa ezindaweni ezidinga amandla amaningi. Ngomsebenzi wokuphatha amandla, abaphathi bangasetha amashejuli ukulawula ngokugcwele ukusetshenziswa kwamandla kwe-OnCell G4302-LTE4 Series kanye nokunciphisa ukusetshenziswa kwamandla lapho kungenzi lutho ukuze kongiwe izindleko.

 

Iklanyelwe ukuphepha okuqinile, i-OnCell G4302-LTE4 Series isekela i-Secure Boot ukuqinisekisa ubuqotho bohlelo, izinqubomgomo ze-firewall ezinezingqimba eziningi zokuphatha ukufinyelela kwenethiwekhi kanye nokuhlunga ithrafikhi, kanye ne-VPN yokuxhumana okukude okuphephile. I-OnCell G4302-LTE4 Series ihambisana nezindinganiso ze-IEC 62443-4-2 eziqashelwa emhlabeni wonke, okwenza kube lula ukuhlanganisa lawa ma-router eselula avikelekile ezinhlelweni zokuphepha kwenethiwekhi ye-OT.

Izici kanye nezinzuzo

 

Imodyuli ye-LTE Cat. 4 ehlanganisiwe enokusekelwa kwebhendi ye-US/EU/APAC

Ukweqiwa kwezixhumanisi zeselula ngokusekelwa kwe-GuaranLink enama-SIM amabili

Isekela ukuphindaphinda kwe-WAN phakathi kweselula ne-Ethernet

Sekela i-MRC Quick Link Ultra yokuqapha okuphakathi kanye nokufinyelela kude kumadivayisi akusayithi

Bona ngeso lengqondo ukuphepha kwe-OT ngesofthiwe yokuphatha i-MXsecurity

Ukusekelwa kokuphathwa kwamandla kokuhlela isikhathi sokuvuka noma izimpawu zokufaka zedijithali, ezifanele izinhlelo zokuthungela izimoto

Hlola idatha yephrothokholi yezimboni ngobuchwepheshe be-Deep Packet Inspection (DPI)

Yakhiwe ngokwe-IEC 62443-4-2 nge-Secure Boot

Idizayini eqinile nencane yezindawo ezinzima

Imininingwane

 

Izici Zomzimba

Izindlu Insimbi
Ubukhulu 125 x 46.2 x 100 mm (4.92 x 1.82 x 3.94 in)
Isisindo 610 g (1.34 lb)
Ukufakwa Ukufakwa kwesitimela se-DIN

Ukufakwa odongeni (ngekhithi ongayikhetha)

Isilinganiso se-IP I-IP402

 

Imikhawulo Yemvelo

Izinga Lokushisa Lokusebenza Amamodeli Ajwayelekile: -10 kuya ku-55°C (14 kuya ku-131°F)

Amamodeli Okushisa Okubanzi: -30 kuya ku-70°C (-22 kuya ku-158°F)

Izinga Lokushisa Lesitoreji (kufakiwe iphakheji) -40 kuya ku-85°C (-40 kuya ku-185°F)
Umswakama Olinganiselwe Wendawo Ezungezile 5 kuya ku-95% (akunciphisi)

 

 

Uchungechunge lwe-MOXA OnCell G4302-LTE4

Igama Lemodeli Ibhendi ye-LTE Izinga Lokusebenza.
I-OnCell G4302-LTE4-EU I-B1 (2100 MHz) / B3 (1800 MHz) / B7 (2600 MHz) / B8 (900 MHz) / B20 (800 MHz) / B28 (700 MHz) -10 kuya ku-55°C
I-OnCell G4302-LTE4-EU-T I-B1 (2100 MHz) / B3 (1800 MHz) / B7 (2600 MHz) / B8 (900 MHz) / B20 (800 MHz) / B28 (700 MHz) -30 kuya ku-70°C
I-OnCell G4302-LTE4-AU I-B1 (2100 MHz) / B3 (1800 MHz) / B5 (850 MHz) / B7 (2600 MHz) / B8 (900 MHz) / B28 (700 MHz) -10 kuya ku-55°C
I-OnCell G4302-LTE4-AU-T I-B1 (2100 MHz) / B3 (1800 MHz) / B5 (850 MHz) / B7 (2600 MHz) / B8 (900 MHz) / B28 (700 MHz) -30 kuya ku-70°C
 

I-OnCell G4302-LTE4-US

I-B2 (1900 MHz) / B4 (1700/2100 MHz (AWS)) / B5

(850 MHz) / B12 (700 MHz) / B13 (700 MHz) / B14

(700 MHz) / B66 (1700 MHz) / B25 (1900 MHz)

/B26 (850 MHz) /B71 (600 MHz)

 

-10 kuya ku-55°C

 

I-OnCell G4302-LTE4-US-T

I-B2 (1900 MHz) / B4 (1700/2100 MHz (AWS)) / B5

(850 MHz) / B12 (700 MHz) / B13 (700 MHz) / B14

(700 MHz) / B66 (1700 MHz) / B25 (1900 MHz)

/B26 (850 MHz) /B71 (600 MHz)

 

-30 kuya ku-70°C

 

I-OnCell G4302-LTE4-JP

I-B1 (2100 MHz) / B3 (1800 MHz) / B8 (900 MHz) /

I-B11 (1500 MHz) / B18 (800 MHz) / B19 (800 MHz) /

I-B21 (1500 MHz)

-10 kuya ku-55°C
 

I-OnCell G4302-LTE4-JP-T

I-B1 (2100 MHz) / B3 (1800 MHz) / B8 (900 MHz) /

I-B11 (1500 MHz) / B18 (800 MHz) / B19 (800 MHz) /

I-B21 (1500 MHz)

-30 kuya ku-70°C

  • Okwedlule:
  • Olandelayo:

  • Bhala umlayezo wakho lapha bese uwuthumela kithi

    Imikhiqizo ehlobene

    • Idivayisi Engenantambo Yezimboni ye-MOXA NPort W2250A-CN

      Idivayisi Engenantambo Yezimboni ye-MOXA NPort W2250A-CN

      Izici kanye Nezinzuzo Ixhumanisa amadivayisi e-serial kanye ne-Ethernet kunethiwekhi ye-IEEE 802.11a/b/g/n Ukucushwa okusekelwe kuwebhu kusetshenziswa i-Ethernet noma i-WLAN eyakhelwe ngaphakathi Ukuvikelwa kokunyuka okuthuthukisiwe kwe-serial, i-LAN, kanye namandla Ukucushwa okukude nge-HTTPS, i-SSH Ukufinyelela idatha okuphephile nge-WEP, i-WPA, i-WPA2 Ukuzulazula okusheshayo kokushintsha okusheshayo okuzenzakalelayo phakathi kwamaphoyinti okufinyelela Ukufakwa kwe-port okungaxhunyiwe ku-inthanethi kanye ne-serial data log Ukufakwa kwamandla okubili (1 screw-type pow...

    • Iseva Yedivayisi Ejwayelekile Yezimboni ye-MOXA NPort 5110

      Iseva Yedivayisi Ejwayelekile Yezimboni ye-MOXA NPort 5110

      Izici kanye nezinzuzo Usayizi omncane wokufakwa kalula Abashayeli be-COM kanye ne-TTY bangempela be-Windows, i-Linux, kanye ne-macOS I-interface ejwayelekile ye-TCP/IP kanye nezindlela zokusebenza eziguquguqukayo I-Windows Utility elula ukuyisebenzisa yokulungiselela amaseva edivayisi amaningi i-SNMP MIB-II yokuphathwa kwenethiwekhi Lungiselela nge-Telnet, isiphequluli sewebhu, noma i-Windows Utility I-resistor yokudonsa ephezulu/ephansi elungisekayo yamachweba e-RS-485 ...

    • Ihabhu le-USB le-MOXA UPort 407 lezinga lezimboni

      Ihabhu le-USB le-MOXA UPort 407 lezinga lezimboni

      Isingeniso I-UPort® 404 kanye ne-UPort® 407 ziyizikhumulo ze-USB 2.0 zezinga lezimboni ezinweba ichweba elilodwa le-USB libe yizikhumulo ze-USB ezingu-4 kanye nezingu-7, ngokulandelana. Izikhumulo zenzelwe ukuhlinzeka ngamazinga okudlulisa idatha e-USB 2.0 Hi-Speed ​​​​480 Mbps yangempela ngechweba ngalinye, ngisho nasezinhlelweni zokusebenza ezisindayo. I-UPort® 404/407 ithole isitifiketi se-USB-IF Hi-Speed, okuyisibonakaliso sokuthi yomibili le mikhiqizo ithembekile, ikhwalithi ephezulu ye-USB 2.0 hubs. Ngaphezu kwalokho,...

    • Idivayisi Yochungechunge Yezimboni Ejwayelekile ye-MOXA NPort 5232I

      Idivayisi Yochungechunge Yezimboni Ejwayelekile ye-MOXA NPort 5232I

      Izici kanye nezinzuzo Umklamo ohlangene wokufakwa kalula Izindlela zesokhethi: Iseva ye-TCP, iklayenti le-TCP, i-UDP Isisetshenziswa se-Windows esilula ukusisebenzisa sokulungiselela amaseva amadivayisi amaningi I-ADDC (Ukulawulwa Kokuqondisa Idatha Okuzenzakalelayo) kwezintambo ezimbili kanye nezintambo ezine-RS-485 SNMP MIB-II yokuphathwa kwenethiwekhi Imininingwane I-Ethernet Interface 10/100BaseT(X) Amachweba (ukuxhumeka kwe-RJ45...

    • I-MOXA UPort 1250 USB To 2-port RS-232/422/485 Serial Hub Converter

      I-MOXA UPort 1250 USB Iya kumachweba amabili i-RS-232/422/485 Se...

      Izici kanye nezinzuzo I-Hi-Speed ​​USB 2.0 yamazinga okudlulisa idatha ye-USB afinyelela ku-480 Mbps Amazinga okudlulisa idatha ye-USB angu-921.6 kbps i-baudrate ephezulu yokudlulisa idatha okusheshayo Abashayeli be-COM ne-TTY bangempela be-Windows, i-Linux, kanye ne-adaptha ye-macOS Mini-DB9-female-to-terminal-block yokuxhuma okulula ama-LED okubonisa umsebenzi we-USB kanye ne-TxD/RxD Ukuvikelwa kokuhlukaniswa kwe-2 kV (kwamamodeli “e-V”) Imininingwane ...

    • I-MOXA EDS-305-M-ST iswishi ye-Ethernet engalawulwa ngamachweba ama-5

      I-MOXA EDS-305-M-ST iswishi ye-Ethernet engalawulwa ngamachweba ama-5

      Isingeniso Amaswishi e-EDS-305 Ethernet ahlinzeka ngesisombululo esingabizi kakhulu sokuxhumeka kwakho kwe-Ethernet yezimboni. Lawa maswishi anamachweba ama-5 ahambisana nomsebenzi wokuxwayisa we-relay owakhelwe ngaphakathi oxwayisa onjiniyela benethiwekhi lapho kwenzeka ukwehluleka kwamandla noma ukuphuka kwamachweba. Ngaphezu kwalokho, amaswishi aklanyelwe izindawo zezimboni ezinzima, njengezindawo eziyingozi ezichazwe yizindinganiso ze-Class 1 Div. 2 kanye ne-ATEX Zone 2. Amaswishi ...